Installation & Fixing Guidelines
HI TECH Roofing, wall cladding, tile, corrugation and accessories are manufactured from the finest high quality raw material coils of PPGI (Pre Painted Galvanized Iron), PPGL (Pre Painted Galvalume) and NCGL (Non Colour Galvalume).
The recommended roof fitting method is as shown below
Installation & Fixing Guidelines Installation & Fixing Guidelines
The Anticapillary Portion Shoudld Come in the Bottom
Lay Eech run of sheets in turn from Bottom to top before moving on to the next run as depicted above. similar procedure for wall cladding too.
 
HI TECH Mandarin Roofing Fixing Details
HI TECH Mandarin Roofing Fixing Details
  • Purlin should come under every alternate tile
  • Each and every end lap should be on top of the purlin.
  • During overlap anti - capillary groove side to be placed on the bottom
  • Precede the sheet lying towards right starting from left.
  • At eave purlin there should be fasteners in every tile.
  • At the intermediate purlin every other tile should have fasteners.
  • Use SDS Screws for fixing the sheet.
  • Use torque adjustable screw gun for fixing screen.
  • Do not overtighten the fastners, set correct torque before drilling.
  • Always store sheet horizontally in stacks, with timber baton.
  • Cover the sheet stored in the open with polythene or tarpaulin with a plenty for ventitlation.
  • Building slope should be minimum 20 degrees
  • Mastic Butyl sealant tape to be used between the sheet overlap for better water leakage arrest
 
Roofing Load Chart
Roofing Load Chart
NOTE
DLLL Dead Load + Live lOad (Deflection Limitation:span/180)
ULD-Wind Uniform Distributed Load Load - Wind (Deflection Limitation Span/120)
Materal Confoming to ASTM A972M Grade 80(Yield Strength 550Mpa) or Equivalent
 

Sheet TK
mm

Load Case
Purlin Spacing Meter
1.0 1.1 .1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0
0.35
udi - DLLL
306.4 230.2 177.3 139.5 111.7 90.8 74.8 62.4 52.5 44.7 38.3
udi - wind
574.6 431.7 332.5 261.5 209.4 170.2 140.3 116.9 98.5 83.8 71.8
0.4
udi - DLLL
395.7 297.3 229 180.1 144.2 117.2 96.6 80.5 67.8 57.7 49.5
udi - wind
741.8 557.4 429.3 337.7 270.4 219.8 181.1 151 127.2 108.2 92.7
0.47
udi - DLLL
521.6 391.9 301.9 237.4 190.1 154.6 127.4 106.2 89.4 76.1 65.2
udi - wind
978.1 734.8 566 445.2 356.4 289.8 238.8 199.1 167.7 142.6 122.3
0.5
udi - DLLL
574.4 432.3 333 261.9 209.7 170.5 140.5 117.1 98.7 83.9 71.9
udi - wind
1078.9 810.6 624.4 491.1 393.2 319.7 263.4 219.4 185 157.3 134.9
0.6
udi - DLLL
736.8 553.6 426.4 335.4 268.5 218.3 179.9 150 126.3 107.4 92.1
udi - wind
1381.6 1038 799.5 628.8 503.5 409.4 337.3 281.2 236.9 201.4 172.7
Galvanized Sheet Color Coated Sheet Air Turbo Ventilator MS Pipe
Roofing Sheet Shade Fibre Sheet Color Coated Coil
PPGI Sheet Structure APVC Sheet PPGI Coil
PPGL Sheet Self - Drilling - Screw Steel PPGL Coil